dc.description.abstract | As resinas compostas vêm ganhando cada vez mais espaço na Odontologia devido a sua qualidade mecânica e estética. As restaurações em resina composta necessitam de uma correta intensidade de luz para que os monômeros resinosos sejam convertidos em polímeros. O presente trabalho teve como objetivo avaliar a intensidade de luz dos aparelhos fotopolimerizadores por meio do teste de microinfiltração marginal. Foram utilizados 3 fotopolimerizadores, sendo 2 de diodo emissor de luz (LED) em 3 técnicas de fotopolimerização (escalonado, ramp e pulsátil) e 1 de lâmpada de quartzo tungstênio halógena (QTH). Foram selecionados 40 molares permanentes nos quais foram realizados preparos cavitários classe V com terminação gengival em cemento e oclusal em esmalte. Os dentes foram divididos aleatoriamente em 4 grupos (n=10), sendo LED Escalonado (LED Esc), LED Pulsátil (LED Pul), LED Ramp (LED Ramp) e QTH Escalonado (QTH Esc), posto isso foi utilizada a resina Bulk Fill (BF) em todas as amostras e a fotopolimerização feita com os respectivos aparelhos sorteados. Foi feita a impermeabilização das amostras de todos os grupos com resina epóxi e esmalte exceto 1 mm das margens das restaurações. Imediatamente após a impermeabilização, os dentes foram imersos em coloração azul de metileno 5% e armazenados a 37 °C em estufa bacteriológica por 4 horas. As amostras foram seccionadas no sentido vestíbulo-lingual no centro das restaurações utilizando disco de carborundum. Os resultados foram submetidos ao teste de Correlação de Pearson entre 3 examinadores diferentes e ao teste de Kruskal Wallis (Dunn). Não houve diferença estatisticamente significante entre os tipos de fotopolimerizadores e nas técnicas de fotopolimerização nos escores de microinfiltração em ambas paredes cavitárias, oclusal e gengival (p>0.05). Comparando as paredes cavitárias, a gengival apresentou maior microinfiltração marginal quando comparada com a oclusal em todos os grupos estudados (px<0.05). Foi possível concluir que o substrato dentário influenciou mais significativamente na microinfiltração do que a técnica ou aparelho utilizado para fotopolimerização da resina Bulk Fill em cavidades classe V. | pt_BR |
dc.description.abstract | The accumulated composite resins gaining more and more space in Dentistry due to their mechanical and aesthetic quality. The restorations in resin composed of a correct light intensity so that the resinous monomers are converted into polymers. The present work aimed to evaluate the light intensity of the photopolymerizing devices by means of the marginal microleakage test. Three photopolymerizers were used, 2 of which were light emitting diode (LED) in 3 photopolymerization techniques (stepped, ramp and pulsating) and 1 halogen tungsten quartz (QTH) lamp. Forty permanent molars were selected in which class V cavity preparations with gingival termination in cement and occlusal enamel were performed. The teeth were randomly divided into 4 groups (n = 10), with Stepped LED (Esc LED), Pulsed LED (Pul LED), Ramp LED (LED Ramp) and Stepped QTH (QTH Esc), since this was used Bulk resin Fill (BF) in all the main ones and the photopolymerization done with the selected devices. All groups were waterproofed with epoxy resin and enamel except 1 mm from the margins of the restorations. Immediately after waterproofing, the teeth were immersed in 5% methylene blue and stored at 37 ° C in a bacteriological oven for 4 hours. The sections were sectioned in the vestibule-lingual direction in the center of the restorations using a carborundum disc. The results were discovered using the Pearson Correlation test between 3 different examiners and the Kruskal-Wallis test (Dunn). There was no statistically significant difference between the types of photopolymerizers and the photopolymerization techniques in the microleakage scores on both cavity, occlusal and gingival walls (p> 0.05). Comparing the cavity walls, the gingival had the highest marginal microleakage when compared to the occlusal one in all studied groups (px <0.05). It was possible to conclude that the dental substrate had a more complete influence on microleakage than the technique or apparatus for photopolymerization of Bulk Fill resin in class V cavities. | pt_BR |
dc.language.iso | por | pt_BR |
dc.publisher | Pontifícia Universidade Católica de Campinas (PUC-Campinas) | pt_BR |
dc.rights | Acesso aberto | pt_BR |
dc.subject | Resina composta | pt_BR |
dc.subject | Fotopolimerização | pt_BR |
dc.subject | Intensidade de luz | pt_BR |
dc.subject | Microinfiltração e resina Bulk Fill | pt_BR |
dc.subject | Composite resin | pt_BR |
dc.subject | Photopolymerization | pt_BR |
dc.subject | Light intensity | pt_BR |
dc.subject | Microleakage and Bulk Fill resin | pt_BR |
dc.title | Avaliação da influência da intensidade de luz dos aparelhos fotopolimerizadores em restaurações com resina composta: teste de microinfiltração marginal | pt_BR |
dc.type | Trabalho de Conclusão de Curso | pt_BR |
dc.contributor.institution | Pontifícia Universidade Católica de Campinas (PUC-Campinas) | pt_BR |
puc.center | Centro de Ciências da Vida (CCV) | pt_BR |
puc.graduateProgram | Não se aplica | pt_BR |
puc.embargo | Online | pt_BR |
puc.undergraduateProgram | Odontologia | pt_BR |